Technical data
  Communication 
  9.2 Communication according to PROFIdrive 
Function Manual 
Function Manual, 06/2012, 6SL3097-4AB10-0BP4 
617 
Error 
value 
Meaning  Remark  Additional 
info 
0x7C  Parameter %s [%s]: Write access 
only in the commissioning state, 
device download 
(device: p0009 = 29). 
–  – 
0x7D  Parameter %s [%s]: Write access 
only in the commissioning state, 
device parameter reset 
(device: p0009 = 30). 
–  – 
0x7E  Parameter %s [%s]: Write access 
only in the commissioning state, 
device ready (device: p0009 = 0). 
–  – 
0x7F  Parameter %s [%s]: Write access 
only in the commissioning state, 
device (device: p0009 not 0). 
–  – 
0x81  Parameter %s [%s] may not be 
written in download. 
–  – 
0x82  Transfer of the control authority 
(master) is inhibited by BI: p0806. 
–  – 
0x83  Parameter %s [%s]: requested BICO 
interconnection not possible 
BICO output does not supply float values. The BICO input, 
however, requires a float value. 
– 
0x84  Parameter %s [%s]: parameter 
change inhibited 
(refer to p0300, p0400, p0922) 
–  – 
0x85  Parameter %s [%s]: access method 
not defined. 
–  – 
0xC8  Below the valid values.  Modification request for a value that, although within 
"absolute" limits, is below the currently valid lower limit. 
– 
0xC9  Above the valid values.  Modification request for a value that, although within 
"absolute" limits, is below the currently valid lower limit 
(e.g. governed by the current converter rating). 
– 
0xCC  Write access not permitted.  Write access is not permitted because an access key is 
not available. 
– 