Technical data
  Communication 
  9.2 Communication according to PROFIdrive 
Function Manual 
Function Manual, 06/2012, 6SL3097-4AB10-0BP4 
615 
Error values in DPV1 parameter responses 
Table 9- 33  Error values in DPV1 parameter responses 
Error 
value 
Meaning  Remark  Additional 
info 
0x00  Illegal parameter number  Access to a parameter which does not exist.  – 
0x01  Parameter value cannot be changed  Modification access to a parameter value which cannot be 
changed. 
Subindex 
0x02  Lower or upper value limit exceeded  Modification access with value outside value limits.  Subindex 
0x03  Invalid subindex  Access to a subindex which does not exist.  Subindex 
0x04  No array  Access with subindex to an unindexed parameter.  – 
0x05  Wrong data type  Modification access with a value which does not match the 
data type of the parameter. 
– 
0x06  Illegal set operation (only reset 
allowed) 
Modification access with a value not equal to 0 in a case 
where this is not allowed. 
Subindex 
0x07  Description element cannot be 
changed 
Modification access to a description element which cannot 
be changed. 
Subindex 
0x09  No description data  Access to a description which does not exist (the 
parameter value exists). 
– 
0x0B  No operating priority  Modification access with no operating priority.  – 
0x0F  No text array exists  Access to a text array which does not exist (the parameter 
value exists). 
– 
0x11  Request cannot be executed due to 
operating status 
Access is not possible temporarily for unspecified reasons.  – 
0x14  Illegal value  Modification access with a value which is within the limits 
but which is illegal for other permanent reasons 
(parameter with defined individual values). 
Subindex 
0x15  Response too long  The length of the present response exceeds the maximum 
transfer length. 
– 
0x16  Illegal parameter address  Impermissible or unsupported value for attribute, number 
of elements, parameter number, subindex or a 
combination of these. 
– 
0x17  Illegal format  Write request: illegal or unsupported parameter data 
format 
– 
0x18  No. of values inconsistent  Write request: a mismatch exists between the number of 
values in the parameter data and the number of elements 
in the parameter address. 
– 
0x19  Drive object does not exist  You have attempted to access a drive object that does not 
exist. 
– 
0x65  Presently deactivated.  You have tried to access a parameter that, although 
available, does not currently perform a function 
(e.g. n control set and access to a V/f control parameter). 
– 
0x6B  Parameter %s [%s]: no write access 
for the enabled controller 
–  – 