Technical data

Communication
9.2 Communication according to PROFIdrive
Function Manual
608 Function Manual, 06/2012, 6SL3097-4AB10-0BP4
Properties
No additional parameters need to be entered in addition to the bus configuration in order
to activate this function, the master and slave must only be preset for this function
(PROFIBUS).
The master-side default setting is made via the hardware configuration, e.g. B. HWConfig
with SIMATIC S7. The slave-side default setting is made via the parameterization
telegram when the bus is ramping up.
Fixed sampling times are used for all data communication.
The Global Control (GC) clock information on PROFIBUS is transmitted before the
beginning of each cycle.
The length of the clock cycle depends on the bus configuration. When the clock cycle is
selected, the bus configuration tool (e.g. HWConfig) supports:
High number of drives per slave/drive unit → longer cycle
Large number of slaves/drive units → longer cycle
A sign-of-life counter is used to monitor user data transfer and clock pulse failures.