E_DIGITAL (digital inputs) 
See function diagram [2498]. 
Table 9- 31  Description of E_DIGITAL (digital inputs) 
Bit  Meaning  Remarks  Parameter 
0  Digital input/output 8 
(DI/DO = 8) 
–  DI/DO 8 on the Control Unit must be parameterized as an input 
(p0728.8 = 0). 
BO: p0722.8
1  Digital input/output 9 
(DI/DO = 9) 
–  DI/DO 9 on the Control Unit must be parameterized as an input 
(p0728.9 = 0). 
BO: p0722.9
2  Digital input/output 10 
(DI/DO = 10) 
–  DI/DO 10 on the Control Unit must be parameterized as an input 
(p0728.10 = 0). 
BO: 
p0722.10 
3  Digital input/output 11 
(DI/DO = 11) 
–  DI/DO 11 on the Control Unit must be parameterized as an input 
(p0728.11 = 0). 
BO: 
p0722.11 
4...7  Reserved  –  –  – 
8  Digital input 0 (DI 0)  –  Digital input DI 0 on the Control Unit  BO: r0722.0 
9  Digital input 1 (DI 1)  –  Digital input DI 1 on the Control Unit  BO: r0722.1 
10  Digital input 2 (DI 2)  –  Digital input DI 2 on the Control Unit  BO: r0722.2 
11  Digital input 3 (DI 3)  –  Digital input DI 3 on the Control Unit  BO: r0722.3 
12...1
5 
Reserved  –  –  – 