Technical data

Communication
9.2 Communication according to PROFIdrive
Function Manual
Function Manual, 06/2012, 6SL3097-4AB10-0BP4
587
XIST_A
Actual position value is displayed
Normalization: 1 corresponds to 1 LU
S_ZSW1B
Safety Info Channel: Status word
Table 9- 22 Description S_ZSW1B
Bit Meaning Remarks Parameter
1 STO active 0 STO active
0 STO not active
r9734.0
1 SS1 active 1 SS1 active
0 SS1 not active
r9734.1
1 SS2 active 2 SS2 active
0 SS2 not active
r9734.2
1 SOS active 3 SOS active
0 SOS not active
r9734.3
1 SLS active 4 SLS active
0 SLS not active
r9734.4
1 SOS selected 5 SOS selected
0 SOS deactivated
r9734.5
1 SLS selected 6 SLS selected
0 SLS not selected
r9734.6
1 Internal event 7 Internal event
0 No internal event
r9734.7
8…11 Reserved
1 SDI positive selected 12 SDI positive selected
0 SDI positive not selected
r9734.12
1 SDI negative selected 13 SDI negative selected
0 SDI negative not selected
r9734.13
1 Emergency retraction requested 14 Emergency retraction requested
0 Emergency retraction not requested
r9734.14
1 Safety message effective 15 Safety message effective
0 No Safety message effective
r9734.15