Technical data
  Commissioning with PROFIBUS 
  3.3 Basic Operator Panel 20 (BOP20) 
Function Manual 
Function Manual, 06/2012, 6SL3097-4AB10-0BP4 
51 
●  Tools → Set PG/PC interface... → Properties 
Activate/deactivate "PG/PC is the only master on the bus". 
Note 
•  Baud rate 
Switching STARTER to a working PROFIBUS: 
STARTER automatically detects the baud rate used by SINAMICS for the PROFIBUS. 
Switching the STARTER for commissioning: 
The Control Unit automatically detects the baud rate set in STARTER. 
•  PROFIBUS addresses 
The PROFIBUS addresses for the individual drive units must be specified in the 
project and must match the address settings on the devices. 
3.3  Basic Operator Panel 20 (BOP20) 
Brief description 
The Basic Operator Panel 20 (BOP20) is a basic operator panel with six keys and a display 
unit with background lighting. The BOP20 can be plugged onto the SINAMICS Control Unit 
and operated. 
The following functions are possible using BOP20 
●  Entering parameters 
●  Display of operating modes, parameters, alarms and faults 
●  Powering-up/powering-down while commissioning 
Further information: See 'Parameterizing using the BOP20 (Basic Operator Panel 20)' 
chapter 