Technical data
  Safety Integrated Functions 
  8.9 Acceptance test and acceptance report 
Function Manual 
Function Manual, 06/2012, 6SL3097-4AB10-0BP4 
527 
Trace evaluation: 
●  Function SDI positive is activated (see bits "Deselect SDI positive" and "SDI positive 
active") 
●  The drive starts moving (time axis approx -300 ms) 
●  Exiting the SDI tolerance window is detected (time axis 0 ms) 
●  Safety messages are initiated (time axis 0 ms; bit "internal event" is set to 0) 
●  Fault response STOP E (corresponds to selecting SOS) is initiated (time axis 0 ms; see 
bit "STOP E active") 
●  The standstill position is only safely monitored (time axis 500 ms; see bit "SOS active") 
after the transition time STOP E to SOS (p9554/p9354) has expired 
●  However, as the axis continues to rotate, the standstill tolerance window is violated (time 
axis approx. 800 ms) 
●  STOP B is initiated (see bit "SS1 active") 
●  The drive is braked to a standstill 
●  Standstill is reached (time axis approx. 850 ms) 
●  STOP A (as follow-up response to STOP B) is activated (see bit "STO active"); at this 
point the speed falls below the shutdown speed SS1 (p9560/p9360) (drops below the 
shutdown speed SS1 before SS1 timer p9556/p9356 has expired). 
Note 
Small time differences (of the order of 2 to 3 Safety clock cycles (here up to 6 ms)) are 
caused by internal calculations and do not present a problem. 