Technical data

Safety Integrated Functions
8.9 Acceptance test and acceptance report
Function Manual
512 Function Manual, 06/2012, 6SL3097-4AB10-0BP4
No. Description Status
C01700, C30700 (STOP A initiated)
Analyze trace:
As soon as r9713[0] leaves the SDI tolerance window, a Safety message becomes
active (r9722.7 = 0).
4.
As consequence, STOP A is initiated and the pulses are canceled (p9721.2 = 1).
5. Save/print the trace and add it to the acceptance report (refer to the example below)
Deselect SDI and safely acknowledge Safety messages
No Safety faults, alarms and messages (r0945[0...7], r2122[0...7], r9747[0...7])
r0046.0 = 1 (drive in "switch-on inhibited" state)
Acknowledge switch-on inhibit and run the drive
6.
Check whether the drive is moving
7. Repeat points 1 to 6 for the opposite direction.
Example trace: SDI (with encoder) with STOP A
%LWWUDFNV
'ULYHBU>@6,PRWLRQGLDJQRVWLFVSRVLWLRQDFWXDOYDOXHORDGVLGHORDGVLGHDFWXDOYDOXHRQWKH&RQWURO8QLW
6',SRVLWLYHDFWLYH
,QWHUQDOHYHQW
672DFWLYH
3XOVHHQDEOH
'HVHOHFW6',
SRVLWLYH
Figure 8-48 Example trace: SDI (with encoder) with STOP A