Safety Integrated Functions   
8.9 Acceptance test and acceptance report 
  Function Manual 
510  Function Manual, 06/2012, 6SL3097-4AB10-0BP4 
Example trace: SSM (with encoder) with hysteresis 
%LWWUDFNV
'ULYHBU>@6,0RWLRQGLDJQRVWLFVVSHHGDFWXDOORDGVLGHVSHHGYDOXHRQ&RQWURO8QLW
660VSHHGEHORZOLPLWYDOXH
Figure 8-47  Example trace: SSM (with encoder) with hysteresis 
Trace evaluation: 
●  Drive is accelerated (time axis from approx. -300 ms) 
●  SSM limit value (p9546/p9346) is exceeded (time axis 0 ms) 
●  Bit "SSM (speed below limit value)" is set to 0 (time axis 0 ms) 
●  Drive is decelerated again (time axis approx. 750 ms) 
●  Hysteresis active: The above named bit is only set to 1 once more if the speed falls below 
the SSM limit value minus the hysteresis value (p9547/p9347) (time axis approx. 1080 
ms) 
Note 
Small time differences (of the order of 2 to 3 Safety clock cycles (here up to 36 ms)) are 