Technical data
  Commissioning with PROFIBUS 
  3.2 STARTER commissioning tool 
Function Manual 
Function Manual, 06/2012, 6SL3097-4AB10-0BP4 
49 
Upgrade the project 
1. Is the project in STARTER? Yes: continue with 3. 
2. Use STARTER to download project to PG: 
–  Connect with target system (go online) 
–  Downloading the project into the PG 
3. Install the latest firmware version for the project. 
–  In the project navigator, right-click Drive unit → Target device → Device version. 
–  For example, select version "SINAMICS S110 V4.3x" -> Change version. 
Update the firmware and load the new project to the target device. 
1. Insert the memory card containing the new firmware version into the Control Unit: 
–  Disconnect the Control Unit from the power supply → 
–  Insert the memory card containing the new firmware version → 
–  Power up the Control Unit again. 
2. Go online and download the project to the target device → Copy RAM to ROM. 
3. Upgrading the firmware for the DRIVE-CLiQ components takes place automatically. 
4. Reset the drive unit using a POWER ON (Control Unit and all DRIVE-CLiQ components). 
The new firmware version is only effective in the DRIVE-CLiQ components from this point 
onwards; it also appears in the version overview. 
3.2.2  Activating online operation: STARTER via PROFIBUS 
Description 
The following options are available for online operation via PROFIBUS: 
●  Online operation via PROFIBUS 