Technical data

Safety Integrated Functions
8.9 Acceptance test and acceptance report
Function Manual
Function Manual, 06/2012, 6SL3097-4AB10-0BP4
495
No. Description Status
Analyze trace:
If r9714[0] exceeds the active SLS limit, a Safety message (r9722.7 = 0) becomes
active
4.
STOP A is initiated as a consequence
5. Save/print the trace and add it to the acceptance report (refer to the example below)
Deselect SLS and acknowledge Safety messages
No Safety faults and alarms (r0945[0...7], r2122[0...7], r9747[0...7])
r0046.0 = 1 (drive in "switch-on inhibited" state)
Acknowledge switch-on inhibit and run the drive
6.
Check whether the drive is moving
Example trace: SLS (with encoder) with STOP A
6723$RU%DFWLYH
'ULYHBU>@6,0RWLRQGLDJQRVWLFVVSHHGDFWXDOORDGVLGHVSHHGYDOXHRQ&RQWURO8QLW
%LWWUDFNV
6HOHFW6/6ELW
6HOHFW6/6ELW
'HVHOHFW6/6
,QWHUQDOHYHQW
6/6DFWLYH
672DFWLYH
$FWLYH6/6OHYHOELW
$FWLYH6/6OHYHOELW
Figure 8-42 Example trace: SLS (with encoder) with STOP A