Technical data
  Safety Integrated Functions 
  8.9 Acceptance test and acceptance report 
Function Manual 
Function Manual, 06/2012, 6SL3097-4AB10-0BP4 
465 
3. Test of the SI function "Safe Brake Control (SBC)" 
–  Required when using Basic and/or Extended Functions 
–  You do not need to prepare trace recording for this test. 
4. Test of the SI function "Safe Stop 2" (SS2) 
–  Only required when used in Extended Functions 
–  This test is also required if you are not explicitly using SS2 but just one function for 
which STOP C occurs as an error response. 
Alternatively, you can also carry out the quantitative test using STOP C yourself, if you 
use the table from section Auto-Hotspot. 
–  Trace recording is required 
5. Test of the SI function "Safe Operating Stop" (SOS) 
–  Only required when used in Extended Functions 
–  This test is also required if you are not explicitly using SOS, but just one function for 
which STOP D or STOP E occurs as an error response. 
Alternatively, you can also carry out the qualitative test using STOP C, STOP D or 
STOP E yourself, if you use the table from section Auto-Hotspot. 
–  Trace recording is required 
6. Test of the SI function "Safely Limited Speed" (SLS) 
–  Only required when used in Extended Functions 
–  A trace recording is required for each SLS limit 
7. Test of the SI function "Safe Direction" (SDI) 
–  Only required when used in Extended Functions 
–  Trace recordings are required for each stop response used 
8. Test of the SI function "Safe Speed Monitor" (SSM) 
–  Only required when used in Extended Functions 
–  Trace recording is required 
C) Functional testing of forced dormant error detection 
Testing the forced dormant error detection of the safety functions for each control type. 
1. Test of the forced dormant error detection of the safety function on the drive 
–  If you are using Basic Functions, you need to activate and then deactivate STO once 
again. 
–  If you are using Extended Functions, you need to carry out a test stop. 