Technical data

Safety Integrated Functions
8.7 Commissioning
Function Manual
444 Function Manual, 06/2012, 6SL3097-4AB10-0BP4
Test stop mode 3
'2
'2
',
9H[W
&8
'2
'2
0
',
Figure 8-28 F-DO circuit, test stop mode 3
Test step
1)
DO+ DO- DIAG signal expectation
0 ... 3 Synchronization
4 OFF OFF HIGH
6 ON ON LOW
8 OFF ON HIGH
10 ON OFF HIGH
12 OFF OFF HIGH
Test sequence for test stop mode 3
1)
You can find a complete list of the steps in the SINAMICS S110 List Manual under message F01773.
Overview of important parameters (see SINAMICS S110 List Manual)
p10001 SI wait time for test stop at DO
p10003 SI forced dormant error detection timer
p10007 BI: SI forced dormant error detection F-DO signal source
p10017 SI digital inputs debounce time
p10046 SI test sensor feedback signal
p10047 SI selection of test mode for test stop