Technical data
Safety Integrated Functions   
8.7 Commissioning 
  Function Manual 
428  Function Manual, 06/2012, 6SL3097-4AB10-0BP4 
8.7  Commissioning 
8.7.1  Safety Integrated firmware versions 
General information 
The Safety firmware on the CU305 Control Unit may have a different version number to the 
overall firmware version. 
The parameters listed below can be used to read the version IDs from the relevant hardware 
components. 
Read the overall firmware version via: 
●  r0018 Control Unit firmware version 
The following firmware data can be read for the Basic Functions: 
●  r9770 SI version, drive-autonomous safety functions (CPU 1) 
The following firmware data can be read for the Extended Functions: 
●  r9590 SI Motion version safe motion monitoring (CPU 1) 
●  r9890 SI version (Sensor Module) 
Basic Functions and Extended Functions 
During the acceptance test for Safety Integrated Basic Functions, the Safety firmware 
versions must be read, logged, and checked against the list below. 
During the acceptance test for the Safety Integrated Extended Functions, the Safety 
firmware versions of the Control Unit and the Sensor Modules or motor with DRIVE-CLiQ 
connection required for the safety functions are to be read, logged, and checked against the 
list below. 
When Extended Functions are used, the firmware requirements for Basic Functions must 
also be fulfilled at all times. 
The list of permissible Safety firmware version combinations which must be used as a 
reference during the test, can be found under "Product Support" at the following address: 
http://support.automation.siemens.com/WW/view/de/28554461 
The procedure for checking is described in the following. 