Technical data

Safety Integrated Functions
8.6 Controlling the safety functions
Function Manual
422 Function Manual, 06/2012, 6SL3097-4AB10-0BP4
The following signals can be called via p10039/p10139 to create the Safe State signal.
Power_removed
SS1_active
SS2_active
SOS_active
SLS_active
SDI_pos_active
SDI_neg_active
Figure 8-20 Safe state selection
The different signals selected through p10039/p10139 are logically linked by means of OR
operation. Result of these logic operations is the "Safe State".
F-DO features
Failsafe design with two digital outputs
Status parameters r10052/r10152
Function diagrams (see SINAMICS S110 List Manual)
2853 Safety Integrated - Extended Functions (F-DO 0)
2856 Safety Integrated - Extended Functions, safe state selection
2857 Safety Integrated - Extended Functions, assignment F-DO 0
Overview of important parameters (see SINAMICS S110 List Manual)
p10039 SI Safe State signal selection
p10042[0..5] SI F-DO 0 signal sources
r10052.0 CO/BO: SI Digital output status (CPU 1)
p10139 SI Safe State signal selection (CPU 2)
p10142[0...5] SI F-DO 0 signal sources (CPU 2)
r10152.0 CO/BO: SI Digital output status (processor 2)