Technical data

Safety Integrated Functions
8.6 Controlling the safety functions
Function Manual
420 Function Manual, 06/2012, 6SL3097-4AB10-0BP4
8.6.3 Note on F-DIs
Note
For enabled Extended Functions, you cannot use F-DIs which are not used for Extended
Functions, for other functions. Although you can connect the F-DIs, Safety Integrated returns
a discrepancy error message as soon as they are activated. This is because these F-DIs are
monitored for discrepancy even when no Safety functions are assigned to them.
Overview of important parameters (see SINAMICS S110 List Manual)
r0722 CO/BO: CU digital inputs, status
p10002 SI discrepancy monitoring time
p10017 SI digital inputs debounce time
p10040 SI F-DI input mode
p10102 SI discrepancy monitoring time (2nd channel)
p10117 SI digital inputs debounce time MM
p10140 SI F-DI input mode (2nd channel)