Technical data

Safety Integrated Functions
8.5 Safety Integrated Extended Functions
Function Manual
396 Function Manual, 06/2012, 6SL3097-4AB10-0BP4
Functional features
Parameters r9720.12/r9720.13 display whether the SDI function is selected.
Parameters rr9722.12/r9722.13 display whether the SDI function is active.
Parameters p9364/p9564 are used to set the tolerance within which a movement in a
non-enabled (non-safe) direction is tolerated.
Parameters p9366/p9566 define the stop response in the case of a fault.
For control via terminals, parameters p10030/p10130 are used to define the terminals for
SDI.
Parameter p10042 is used to define whether the SDI status in the status display of the
F-DO is taken into account.
If "SDI positive" is selected, the following value is set automatically:
r9733[1] = 0 (setpoint limitation negative)
If "SDI "negative" is selected, the following value is set automatically:
r9733[0] = 0 (setpoint limitation positive)
The absolute setpoint speed limit is available in r9733[2].
7LPH
$FWXDOYHORFLW\YDOXH
9HORFLW\VHWSRLQW
6HOHFW
6',
SRVLWLYH
'HVHOHFW6',SRVLWLYH
6',SRVLWLYHDFWLYH
'HOD\WLPH
S S
$FWLYDWLRQ
6',
SRVLWLYH
'HVHOHFW
6',
SRVLWLYH
'HVHOHFW6',QHJDWLYH
6',QHJDWLYHDFWLYH
'LUHFWLRQPRQLWRULQJ
9HORFLW\
352),VDIH
Figure 8-13 Functional principle SDI with encoder