Technical data

Safety Integrated Functions
8.5 Safety Integrated Extended Functions
Function Manual
374 Function Manual, 06/2012, 6SL3097-4AB10-0BP4
Responses
Speed limit violated (SAM):
STOP A
Safety message C01706/C30706
Standstill tolerance violated in p9330/p9530 (SOS):
STOP B with subsequent STOP A
Safety message C01707/C30707
System errors:
STOP F with subsequent STOP A
Safety message C01711/C30711
Overview of important parameters (see SINAMICS S110 List Manual)
p1135[0...n] OFF3 ramp-down time
p9301 SI Motion enable safety functions (CPU 2)
p9501 SI Motion enable safety functions (CPU 1)
p9330 SI Motion standstill tolerance (CPU 2)
p9530 SI Motion standstill tolerance (CPU 1)
p9348 SI Motion SAM actual speed tolerance (CPU 2)
p9548 SI Motion SAM actual speed tolerance (CPU 1)
p9352 SI Motion transition time STOP C to SOS (CPU 2)
1)
p9552 SI Motion transition time STOP C to SOS (CPU 1)
1)
r9722.0...15 CO/BO: SI Motion drive-integrated status signals
1)
STOP C corresponds to SS2.