Technical data
Safety Integrated Functions
8.5 Safety Integrated Extended Functions
Function Manual
Function Manual, 06/2012, 6SL3097-4AB10-0BP4
365
8.5 Safety Integrated Extended Functions
Note
You can ask your local sales office regarding the PFH values of the individual safety
components of the SINAMICS S110 (also refer to the Section "Probability of failure of safety
functions").
8.5.1 Extended Functions "with encoder" / "without encoder"
For activation of the Safety Integrated functions "with encoder" and "without encoder", set
the parameters p9306 and p9506 (factory setting = 0). You can also make this setting by
selecting "with encoder" or "without encoder" on the Safety Integrated STARTER screen.
This STARTER screen can be found for each drive under "Functions" → "Safety Integrated".
● Operation with encoder
p9306 = p9506 = 0
● Operation without encoder
p9306 = p9506 = 1
or
p9306 = p9506 = 3
"Park" mode for Safety Integrated Extended Functions "with encoder"
Note
When a drive object for which Safety Integrated Extended Functions with encoder are
enabled is switched to "Park" mode, the Safety Integrated software responds by selecting
STO without generating a separate message. This internal STO selection is displayed in
parameter r9772.19.
Restrictions for Safety Integrated Extended Functions "without encoder"
The following restrictions apply for the Safety Extended Functions "without encoder":
Operation only with synchronous motors of the series
1 SIEMOSYN (only with U/f control)
No operation for units with the following design
1 Blocksize GX