Technical data
Safety Integrated Functions
8.2 General information about SINAMICS Safety Integrated
Function Manual
336 Function Manual, 06/2012, 6SL3097-4AB10-0BP4
Prerequisites for the Extended Functions
● Safety Integrated Extended Functions can only be operated with the relevant license. The
associated license key is entered in parameter p9920 in ASCII code. The license key can
be activated via parameter p9921 = 1. Alternatively, you can enter the license key via the
STARTER button "License Key".
For information on how to generate the license key for the product "SINAMICS Safety
Integrated Extended Functions", read the section "Licensing". An insufficient license is
indicated via the following alarm and LED:
– A13000 → License not sufficient
– LED RDY → Flashes greed/red at 0.5 Hz
● Activation via PROFIsafe or safe on-board terminals
● An activated speed controller in the drive
● Overview of hardware components that support the Extended Functions:
– CU305 Control Unit
– Power Modules blocksize PM340
– Sensor Modules SMC20, SME20/25
– Motors with DRIVE-CLiQ interface (not with resolver encoder)
– Safe Brake Relay (SBR)
8.2.2 Control of Safety Integrated functions
Safety Integrated functions can be controlled via on-board terminals or via a PROFIsafe
telegram using PROFIBUS or PROFINET. The Extended Functions can be controlled via on-
board terminals or PROFIsafe, control of the Basic Functions can be selected via on-board
terminals (F-DI 0) or PROFIsafe and on-board terminals (F-DI 0).
NOTICE
PROFIsafe or terminals
With a Control Unit, control of the Extended Functions is only possible using PROFIsafe or
on-board terminals. Mixed operation is not permissible.