Technical data
Drive functions
7.3 Function modules
Function Manual
282 Function Manual, 06/2012, 6SL3097-4AB10-0BP4
Overview of important parameters (see SINAMICS S110 List Manual)
Setpoint limitation
● p1080[D] Minimum speed
● p1082[D] Maximum speed
● p1083[D] CO: Speed limit in positive direction of rotation
● r1084 Speed limit positive effective
● p1085[C] CI: Speed limit in positive direction of rotation
● p1086[D] CO: Speed limit negative direction of rotation
● r1087 Speed limit negative effective
● p1088[C] DI: Speed limit negative direction of rotation
● r1119 Ramp-function generator setpoint at the input
Suppression bandwidths
● p1091[D] Suppression speed 1
● ...
● p1094[D] Suppression speed 4
● p1101[D] Suppression speed bandwidth
Parameterization with STARTER
The "speed limitation" parameter screen is selected by activating the following icon in toolbar
of the STARTER commissioning tool:
Figure 7-63 STARTER icon for "speed limitation"
7.3.7.9 Ramp-function generator
Description
The ramp-function generator is used to limit acceleration in the event of abrupt setpoint
changes, which helps prevent load surges throughout the drive train. The ramp-up time
p1120[D] and ramp-down time p1121[D] can be used to set mutually independent
acceleration and deceleration ramps. This allows a controlled transition to be made in the
event of setpoint changes.
The maximum speed p1082[D] is used as a reference value for calculating the ramps from
the ramp-up and ramp-down times. A special adjustable ramp can be set via p1135 for quick
stop (OFF3), e.g. for rapid controlled deceleration when an emergency OFF button is
pressed.