Technical data
Drive functions
7.3 Function modules
Function Manual
Function Manual, 06/2012, 6SL3097-4AB10-0BP4
279
Parameterization with STARTER
The "speed setpoint" parameter screen is selected via the following icon in the toolbar of the
STARTER commissioning tool:
7.3.7.7 Direction limitation and setpoint inversion
Description
A reverse operation involves a direction reversal. Selecting setpoint inversion p1113[C] can
reverse the direction in the setpoint channel.
Parameter p1110[C] or p1111[C] can be set respectively to prevent input of a negative or
positive setpoint via the setpoint channel. However, the following settings for minimum speed
(p1080) in the setpoint channel are still operative. With the minimum speed, the motor can
turn in a negative direction, although p1110 = 1 is set.
6XSSUHVVLRQEDQGZLGWKV
6HWSRLQWOLPLWLQJ
%ORFNSRVLWLYHGLUHFWLRQRIURWDWLRQ
%ORFNQHJDWLYHGLUHFWLRQRIURWDWLRQ
6HWSRLQWLQYHUVLRQ
5DPSIXQFWLRQJHQHUDWRU
0RWRUFRQWURO
S>&@
S>&@
S>&@
Figure 7-61 Direction of rotation limiting and direction of rotation changeover
Function diagrams (see SINAMICS S110 List Manual)
● 1550 Setpoint channel
● 3040 Direction limitation and direction reversal