Technical data
Drive functions   
7.3 Function modules 
  Function Manual 
242  Function Manual, 06/2012, 6SL3097-4AB10-0BP4 
Set reference point 
The reference point can be set using a 0/1 edge at binector input p2596 (set reference point) 
if no traversing commands are active and the actual position value is valid (p2658 = 1 
signal). 
A reference point can also be set in conjunction with an intermediate stop. 
The current actual position of the drive is set here as the reference point using the 
coordinates specified by connector input p2598 (reference point coordinates). The setpoint 
(r2665) is adjusted accordingly. 
This function also uses actual position value correction for the position controller (p2512 and 
p2513). Connector input p2598 is connected to adjustable parameter p2599 as standard. 
The binector input is not effective for the traversing task being presently executed. 
Absolute encoder adjustment 
Absolute encoders must be adjusted while commissioning. After the machine has been 
powered-down the position information of the encoder is kept. 
When p2507 = 2 is entered, using the reference point coordinate in p2599, an offset value 
(p2525) is determined. This is used to calculate the position actual value (r2521). Parameter 
p2507 signals the adjustment with a "3" - in addition bit r2684.11 (reference point set) is set 
to "1". 
The offset of the encoder adjustment (p2525) should be saved in a non-volatile fashion 
(RAM to ROM) to permanently save it. 
Note 
If an adjustment is lost on an already adjusted axis, the axis will remain unadjusted even 
when the drive unit is switched OFF/ON. The axis needs to be adjusted again in such cases.
CAUTION 
During adjustment with the rotary absolute encoder, a range is aligned symmetrically 
around the zero point with half the encoder range within which the position is restored after 
switch off/on. If position tracking is deactivated (2720.0 = 0), only one encoder overflow is 
permitted in this range (further details are given in the chapter titled Position controller → 
Position actual value conditioning). Once adjustment has been carried out, the range must 
not be exited because a unique reference between the actual encoder value and the 
mechanical components cannot be established outside the range. 
If the reference point p2599 is in the encoder range, the actual position value is set in line 
with the reference point during adjustment. Otherwise, it is set to a corrected value in the 
encoder range. 
No overflow occurs with linear absolute encoders, which means that the position can be 
restored within the entire traversing range after switch on/off once adjustment has been 
carried out. During adjustment, the actual position value is set in line with the reference 
point. 