Technical data

Drive functions
7.3 Function modules
Function Manual
240 Function Manual, 06/2012, 6SL3097-4AB10-0BP4
Limitation is effective:
In jog mode
When traversing blocks are processed
When setpoints are defined directly/MDI for positioning and setup
during referencing
During stop responses due to alarms
Jerk limitation is not active when messages are generated with stop responses OFF1 / OFF2
/ OFF3.
Function diagrams (see SINAMICS S110 List Manual)
3630 Traversing range limits
Overview of important parameters (see SINAMICS S110 List Manual)
p2571 EPOS maximum velocity
p2572 EPOS maximum acceleration
p2573 EPOS maximum deceleration
p2646 CI: EPOS velocity override
Software limit switches
p2578 CI: EPOS software limit switch, minus signal source
p2579 CI: EPOS software limit switch, plus signal source
p2580 CO: EPOS software limit switch, minus
p2581 CO: EPOS software limit switch, plus
p2582 BI: EPOS software limit switch activation
r2683 CO/BO: EPOS status word 1
STOP cam
p2568 BI: EPOS STOP cam activation
p2569 BI: EPOS STOP cam, minus
p2570 BI: EPOS STOP cam, plus
r2684 CO/BO: EPOS status word 2