Technical data

Drive functions
7.3 Function modules
Function Manual
Function Manual, 06/2012, 6SL3097-4AB10-0BP4
229
Following error monitoring is activated via p2546 (following error tolerance). If the absolute
value of the dynamic following error (r2563) is greater than p2546, fault F07452 is output and
bit r2648.8 is reset.
&DPVZLWFKLQJVLJQDO
U
V
V
&DPVZLWFKLQJVLJQDO
U
&DPVZLWFKLQJSRVLWLRQ
S
&DPVZLWFKLQJSRVLWLRQ
S
Figure 7-46 Cam controllers
The position controller has two cam controllers. If cam position p2547 or p2548 is passed in
the positive direction (p2521 > p2547 or 2548), then cam signals r2683.8 and r2683.9 are
reset.
Function diagrams (see SINAMICS S110 List Manual)
4020 Zero-speed / positioning monitoring
4025 Dynamic following error monitoring, cam controllers
Overview of important parameters (see SINAMICS S110 List Manual)
p2530 CI: LR setpoint position
p2532 CI: LR actual position value
p2542 LR standstill window
p2543 LR standstill monitoring time
p2544 LR positioning window
p2545 LR positioning monitoring time
p2546 LR dynamic following error monitoring tolerance
p2547 LR cam switching position 1
p2548 LR cam switching position 2
p2551 BI: LR setpoint message present
p2554 BI: LR travel command message active
r2563 CO: LR latest following error
r2683.8 Actual position value <= cam switching position 1
r2683.9 Actual position value <= cam switching position 2
r2684 CO/BO: EPOS status word 2