Technical data

Drive functions
7.3 Function modules
Function Manual
204 Function Manual, 06/2012, 6SL3097-4AB10-0BP4
7.3.2 Technology controller
7.3.2.1 Features
Simple control functions can be implemented with the technology controller, e.g.:
Level control
Dancer position/tension control
Pressure control
Flow control
Simple closed-loop control without higher-level controller
The technology controller features:
Separate fixed values
Integrated motorized potentiometer
Technology controller with:
Two scalable setpoints
Ramp-function generator in setpoint channel
Filter for actual value and setpoint channel
Two modes for derivative component injection
Pre-control
Output ramp with limits
Scalable output signal
7.3.2.2 Description
Motorized potentiometer
This function is used to simulate an electromechanical potentiometer for setpoint input.
Separate binector inputs for higher (p2235) and lower (p2236) are used to adjust the input
setpoint: The potentiometer limits are defined within maximum (p2237) and minimum
(p2238) values. The setpoint input is routed to an internal ramp-function generator, for which
both a ramp-up (p2247) and a ramp-down (p2248) time, as well as an initial value (p2240)
can be defined. Initial rounding can be activated to fine-tune the setpoint, whereby the
acceleration of the setpoint is calculated as follows:
a = 0.0001·
MAX
[p2237; |p2238|] · 0.13
2
The connector output of the motorized potentiometer (r2250) can, for example, be used as a
setpoint for the technology controller. The motorized potentiometer requires the OFF1
enable for operation.