Technical data

Drive functions
7.1 Servo control
Function Manual
168 Function Manual, 06/2012, 6SL3097-4AB10-0BP4
Overview of important parameters (see SINAMICS S110 List Manual)
Adjustable parameters
p1240 Vdc controller or Vdc monitoring configuration
p1244 DC link voltage threshold, upper
p1248 DC link voltage threshold, lower
p1250 Vdc controller proportional gain
Display parameters
r0056.14 Vdc_max controller active
r0056.15 Vdc_min controller active
7.1.15 Travel to fixed stop
Description
This function can be used to move a motor to a fixed stop at a specified torque without a
fault being signaled. When the stop is reached, the specified torque is built up and remains
applied.
The desired torque derating is brought about by scaling the upper/motor-mode torque limit
and the lower/regenerative-mode torque limit.
Application examples
Screwing parts together with a defined torque.
Moving to a mechanical reference point.
Signals
When PROFIBUS telegrams 2 to 4 are used, the following are automatically interconnected:
Control word 2, bit 8
Status word 2, bit 8
Also with PROFIdrive telegrams 102 and 103:
Message word, bit 1
Process data M_red to the scaling of the torque limit