Technical data

Drive functions
7.1 Servo control
Function Manual
146 Function Manual, 06/2012, 6SL3097-4AB10-0BP4
p0640 Current limit
p1082 Maximum speed
p1317 V/f control activation
p1318 V/f control ramp-up/ramp-down time
p1319 V/f control voltage at zero frequency
p1326 V/f control programmable characteristic frequency 4
p1327 V/f control programmable characteristic voltage 4
p1338[0...n] V/f control mode resonance damping gain
p1339[0...n] V/f control mode resonance damping filter time constant
p1345[0...n] DC brake proportional gain
p1346[0...n] DC brake integral time
p1349[0...n] V/f control mode resonance damping maximum frequency
p1498[0...n] Load moment of inertia
p1520[0...n] CO: Torque limit, upper/motoring
p1521[0...n] CO: Torque limit, lower/regenerative
p1530[0...n] Motor mode power limit
p1531[0...n] Regenerative mode power limit
7.1.10 Optimizing the current and speed controller
General information
CAUTION
Controller optimization may only be performed by skilled personnel with a knowledge of
control engineering.
The following tools are available for optimizing the controllers:
"Function generator" in STARTER
"Trace" in STARTER
"Measuring function" in STARTER
Measuring sockets on the Control Unit
Optimizing the current controller
The current controller is initialized when the system is commissioned for the first time and is
adequately optimized for most applications.