Technical data

Drive functions
7.1 Servo control
Function Manual
140 Function Manual, 06/2012, 6SL3097-4AB10-0BP4
General low-pass with reduction
Table 7- 6 Example of general low-pass with reduction
STARTER filter parameters Amplitude log frequency curve Phase frequency curve
Characteristic frequency f
Abs
= 500 Hz
Damping D = 0.7
Reduction Abs = -10 dB
$EV G%
I
$EV
+]
G%
Conversion to parameters for general order filters:
Numerator natural frequency f
Z
= f
Abs
(start of reduction)
Numerator damping:
$EV
$EV
=
I
I


Denominator natural frequency f
N
Denominator damping D
N