Technical data

Drive functions
7.1 Servo control
Function Manual
Function Manual, 06/2012, 6SL3097-4AB10-0BP4
135
Commissioning with STARTER
The "current controller" parameter screen is selected via the following icon in the toolbar of
the STARTER commissioning tool:
Figure 7-12 STARTER icon for "current controller"
Function diagrams (see SINAMICS S110 List Manual)
5710 Current setpoint filters
5714 Iq and Id controller
5722 Specified field current, flux reduction, flux controller
Overview of important parameters (see SINAMICS S110 List Manual)
Closed-loop current control
p1701[0...n] Current controller reference model dead time
p1715[0...n] Current controller P gain
p1717[0...n] Current controller integral time
Current and torque limitation
p0323[0...n] Maximum motor current
p0326[0...n] Stall torque correction factor
p0640[0...n] Current limit
p1520[0...n] CO: Torque limit, upper/motoring
p1521[0...n] CO: Torque limit, lower/regenerative
p1522[0...n] CI: Torque limit, upper/motoring
p1523[0...n] CI: Torque limit, lower/regenerative
p1524[0...n] CO: Torque limit, upper/motoring, scaling
p1525[0...n] CO: Torque limit, lower/regenerative scaling
p1528[0...n] CI: Torque limit, upper/motoring, scaling
p1529[0...n] CI: Lower or regenerative torque limit scaling
p1530[0...n] Motor mode power limit
p1531[0...n] Regenerative mode power limit
p1532[0...n] Torque offset torque limit