Technical data
  Drive functions 
  7.1 Servo control 
Function Manual 
Function Manual, 06/2012, 6SL3097-4AB10-0BP4 
127 
7.1.4  Torque-controlled operation 
Description 
An operating mode switchover (p1300) or binector input (p1501) can be used to switch from 
speed control to torque control mode. All torque setpoints from the speed control system are 
rendered inactive. The setpoints for torque control mode are selected by parameterization. 
Properties 
●  Switchover to torque control mode via: 
–  Operating mode selection 
–  Binector input 
●  Torque setpoint can be specified: 
–  The torque setpoint source can be selected 
–  The torque setpoint can be scaled 
–  An additional torque setpoint can be entered 
●  Display of the overall torque 
Commissioning of torque control mode 
1. Set torque control mode (p1300 = 23; p1501 = "1" signal) 
2. Specify torque setpoint 
–  Select source (p1511) 
–  Scale setpoint (p1512) 
–  Select supplementary setpoint (1513) 
HJS
>@
S>&@
S>&@
S>&@
U
Figure 7-6  Torque setpoint 
3. Activate enable signals 