Technical data

Drive functions
7.1 Servo control
Function Manual
Function Manual, 06/2012, 6SL3097-4AB10-0BP4
127
7.1.4 Torque-controlled operation
Description
An operating mode switchover (p1300) or binector input (p1501) can be used to switch from
speed control to torque control mode. All torque setpoints from the speed control system are
rendered inactive. The setpoints for torque control mode are selected by parameterization.
Properties
Switchover to torque control mode via:
Operating mode selection
Binector input
Torque setpoint can be specified:
The torque setpoint source can be selected
The torque setpoint can be scaled
An additional torque setpoint can be entered
Display of the overall torque
Commissioning of torque control mode
1. Set torque control mode (p1300 = 23; p1501 = "1" signal)
2. Specify torque setpoint
Select source (p1511)
Scale setpoint (p1512)
Select supplementary setpoint (1513)
HJS
>@

S>&@

S>&@
S>&@
U



Figure 7-6 Torque setpoint
3. Activate enable signals