Operating Instructions and Installation Instructions
12
en
VI.
Electrical connection 230 V AC
To guarantee compliance to relevant safety regulations, an
all-pole separator must be fitted during installation. The con-
tact opening must be at least 3 mm.
If the appliance is connected to the power supply by a plug,
the disconnecting device is not required if the plug is acces-
sible to the user.
Appliances fitted with plugs may only be connected to cor-
rectly earthed electrical sockets. Do not use multiway adap-
tors or pushon terminal strips.
Do not connect the appliance to the power supply until it is
mounted on the wall and filled with water.
Attention!
Only appliance installation with fixed connection is
permissible in wet areas.
■ Remove screws 1 and 2.
■ Pull off temperature selector switch.
■ Remove screw 3.
■ Lift off the housing cover.
■ Connect electrical cable 4 to terminal 5.
■ Replace the housing cover and screw it on.
VII.
Limiting the water temperature
■ Fig. 1: Insert the screwdriver into gap a and remove
cover b.
■ Fig. 2: Insert pin c into one of the 4 holes in order to limit
the temperature:
Hole C: ≈ 35 °C
Hole B: ≈ 45 °C
Hole A: ≈ 55 °C
Hole O: ≈ 75 °C
■ Fig. 3: Replace cover b.
Startup
Attention!
Fill the appliance with water before inserting the
mains plug or turning on the mains voltage!
Otherwise the temperature protection will trip and
has to be reset by a trained service professional.
VIII.
Flow rate setting DO15652
■ Rinse out the appliance by fully opening the hot water
tap.
■ Set the flow rate as per DIN 44531 or according to the
specifications of the fittings manufacturer:
max. flow rate: 10 l/min, i. e. the water flows out at a rate
of 1 litre in 6 seconds.
■ Set the flow rate by turning the screw valve on the upper
side of the mixer tap.
First heat-up
■ Turn the temperature selector switch to position “O”.
■ Switch on the fuses or insert the plug into the mains
socket.
■ Turn the temperature selector switch to position „III“.
■ Monitor the heating-up process (see „Technical Data“ for
heating times).
■ Check the temperature.
■ Turn the temperature selector switch to position „e“.
■ Hand over the installation and operating instructions to
the user and explain how the appliance operates.
■ Instruct the user regarding the necessity of regular
descaling.
Technical Data
DG15602
DO15652
Capacity
[l] 15.0
Rated output
[kW] 2
Rated voltage
[V] 230
Rated pressure
pressure-resistant operation [MPa (bar)] 0.6 (6)
unpressurised operation [MPa (bar)] 0 (0)
Weight
empty [kg] 11
filled [kg] 26
Heat-up time
from 12 °C to 60 °C [min] 25
from 12 °C to 75 °C [min] 75
Energy efficiency class
A
Hot water heating energy
efficiency
[%] 36.1
Load profile
XXS
Annual energy consumption
[kWh] 510
Daily energy consumption
[kWh] 2.391
Sound power level
[dB] 15