Catalog
Actuators for lighting (KNX PL-Link)
UP 510/03 UP 525/03 UP 510/13 UP 525/13 RS 510/23 RS 525/23 RL 512/23
Applications
Switching ⦁ ⦁ ⦁ ⦁ ⦁ ⦁ ⦁
Dimming (R, L, C) ⦁ ⦁ ⦁
Outputs
Number of outputs 2 1 2 1 2 1 1
Switching current (A) 10* 10* 10* 16**
Rated power (VA) 10…250 10…250 10…250
Mounting
Flush-mounted
(under push buttons)
⦁ ⦁
Flush-mounted ⦁ ⦁
Room control box (AP 118/01) ⦁ ⦁ ⦁
Room control box (AP 641/01) ⦁ ⦁ ⦁
Integration into DXR2..
Data points 2 1 2 1 2 1 1
KNX PL-Link bus load (mA) 10 10 10 10 10 10 10
* For resistive loads
** For resistive loads, AX loads (200 μF) and direct current at 24 V DC
Actuators for shading (KNX PL-Link)
UP 520/03 UP 520/13 RS 520/23 RL 521/23
Applications
Blinds with slats ⦁ ⦁ ⦁ ⦁
Shutters ⦁ ⦁ ⦁ ⦁
Outputs
Number of outputs 1 1 1 2
Switching current (A) 6* 6* 6* 6*
Mounting
Flush-mounted
(under push buttons)
⦁
Flush-mounted ⦁
Room control box (AP 118/01) ⦁ ⦁
Room control box (AP 641/01) ⦁ ⦁
Integration into DXR2..
Data points 2 2 2 4
KNX PL-Link bus load (mA) 10 10 10 10
* For resistive loads
Central functions
Application can be configured from these functions:
• Central operation group including room operating mode and start
optimization, set points and seasonal compensation, light, shading
and forced emergency commands
• Demand-controlled hot water supply system, includes temperature
set point
• Demand-controlled chilled water supply system, includes temperature
set point, shift to avoid condensation by collecting condensation
monitors, free cooling calculation
• Demand-controlled 2-pipe heating / cooling water supply system,
includes temperature set point, changeover, free cooling calculation
• Demand-controlled air handling unit (supply and extract air), includes
temperature set point, maximum humidity set point, pressure set point,
maintain minimal central air volume, flow deviation calculation,
summed air volume set points
• Variable air volume (VAV) emergency group, includes shutdown,
extract, pressurization or purge
• Central weather station information, includes outside temperature,
outside brightness, outside solar radiation, outside wind speed,
outside precipitation
• Central facade functions for shading, includes brightness calculation,
central operation group for facade, glare protection
• Shading central protection groups for wind protection, precipitation
protection, frost protection, staged distribution for central blind
commands in large buildings
Central weather station controller Central facade controller
T
H
P
Lux
Lux
Lux
Lux
Outside
temperature
Relative
outside
humidity
Atmospheric
pressure
Wind speed Precipitation
detector
Brightness
with 1
sensor
Brightness
with 3
sensor
(E,S,W)
(E,N,W)
Solar
radiation
DI 1
AI 1 1 1 1 1 1–3 1
Push button
(KNX PL-Link)
DXR2.. Type DXR2..18.. DXR2..18..
Central HVAC supply controller Central emergency controller
Operating
mode
groups
Light
manual
central
operation
Shading
manual
central
operation
Forced
emergency
position for
shading
Forced
emergency
command
for lighting
Forced
emergency
shutdown
air supply
Forced
smoke
extraction
(exhaust air)
Forced smoke
pressur ization
(supply air)
DI 1–4 1 1 1–2 1–2 1–2
AI
Push button
(KNX PL-Link)
4* 4*
DXR2.. Type DXR2..18.. DXR2..18..
* Either 1 device UP220 for 2 outputs or 2 devices UP221 / UP285 for 1 output each
4–14
4–15
1 1
3
2
3
2
4 4
Room automation
Overview and selection tools
Room automation
Overview and selection tools