User Guide

Alarms
Alarms and Event Treatment Reference
3
105 | 393
Siemens
User Guide Version 3.0
A6V10415471
Building Technologies
2017-11-30
Information
The following become visible only when the event descriptor is selected:
: Displays the History Database dialog box for that Event ID, where you
can add a note for the event. See Entering an Event Note in the History
Database [➙ 81].
: Displays the information text, which indicates technical information about
a field point. It also displays the same information shown in the Message Text
column. The intervention text may or may not be available to you. See Viewing
the Inline Information Text [➙ 81].
(start Investigative Treatment) or (start Assisted Treatment). See
Handling an Event with Investigative Treatment [➙ 71] and Handling an Event
with Assisted Treatment [➙ 72].
NOTE:
You cannot resize Information column.
Event Status
Describes the status of the event. For example: Unprocessed, Ready to be
reset, and so on. See Event Status and Suggested Action Reference [➙ 110].
Source Status
Describes the status of the event source: Active (event source is in an off-normal
condition) or Quiet (event source is back to normal).
Date/Time
Date and time when the event occurred. Typically, event time displays with
resolution hh:mm:ss. However, in special cases, it will display with resolution
hh:mm:ss:ms.
ID
Unique number that identifies the event. This number has an upper limit. The
numbering restarts when this limit is reached.
In Process by
Indicates which user is processing an event. Depending on the type of Desigo CC
client you’re working one of the following may display:
Installed Client: [computer name]/[full name of the logged-on
user]
If the computer/user data was not specified in the configuration,
[localhost]+[user’s short name] displays instead.
Web Client or Web App Client: Web Client/[Operator’s full name].
Furthermore, for recurrences
1)
of the same event, this column displays the entire list
of computer/users that are processing that event.
1)
Recurring events are not allowed in UL 864-compliant and ULC S527-compliant
fire stations, Danger Management AT, and Total Building Solution NA profiles.
Suggested
action
Describes the next action the operator should take for handling the event. See
Event Status and Suggested Action Reference [➙ 110].
Category
Describes the event category. See Event Categories Reference.
Discipline
Describes the discipline to which the event belongs. See Event Disciplines
Reference [➙ 109].