Engineering Documentation
Table Of Contents
- Copyright Notice
- 1 About this document
- 2 Desigo Control Point Operation engineering topics
- 2.1 Tool-free configuration of a Desigo Control Point device
- 2.1.1 Connecting to the Desigo Control Point device
- 2.1.2 Performing the initial login
- 2.1.3 Configuring the Network port for IP (PXG3.Wx00 and PXM… touch panel)
- 2.1.4 Activating the application (PXG3.Wx00 and PXM… touch panel)
- 2.1.5 Assigning devices to the Desigo Control Point device
- 2.1.6 Updating the Network port for a browser connection (PXM… touch panel)
- 2.1.7 Subscribing to the time master and time synchronization for Assigned devices
- 2.1.8 Configuring for kiosk graphics on a touch panel
- 2.2 Tool-free commissioning of the Operation application
- 2.3 Data point integration overview
- 2.4 Plant view Tools
- 2.4.1 Using the graphics wizard to create a graphic
- 2.4.2 Editing a graphic
- 2.4.3 Removing a graphic
- 2.4.4 Displaying the URL of a graphic
- 2.4.5 Exporting graphics for sharing across jobs
- 2.4.6 Importing graphics
- 2.4.7 Enabling graphics and kiosks for room users to view
- 2.4.8 Defining graphics as a startup page
- 2.5 Working with kiosk graphics
- 2.6 Using engineering notations
- 2.1 Tool-free configuration of a Desigo Control Point device
- 3 Graphics engineering with Graphics Builder
- 3.1 Graphics Builder overview
- 3.2 Using the Builder pane tools
- 3.3 Graphics libraries
- 3.4 Workflows
- 3.5 Working with dashboards
- 3.5.1 The Facility manager dashboard user interface
- 3.5.2 The Public dashboard user interface
- 3.5.3 Adding and editing a text box
- 3.5.4 Adding or replacing a background image
- 3.5.5 Adding information from a trended data point
- 3.5.6 Adding external media to a dashboard
- 3.5.7 Working with gauges
- 3.5.8 Editing charts
- 3.6 Creating end-user room graphics
- 3.7 Advanced functionality
- 4 Tips and tricks
- 4.1 Updates required after a time zone change
- 4.2 APPLY BATCH TAGS > Custom Filter button is reserved for future use
- 4.3 Graphic components within models cannot be modified
- 4.4 A graphic with relative binding that includes data points from different branches of the hierarchy cannot be created at the Root level
- 4.5 Relative hyperlinks cannot be added to a graphic at the Root level
- 4.6 Relative hyperlinks in a graphic are broken if the graphic is engineered offline and then imported to another device
- 4.7 Haystack interface
- 4.8 Automatic logout from the Operation application causes Graphics Builder to temporarily stop working
- Index
Desigo Control Point Operation engineering topics
Data point integration overview
30 | 138
Siemens
A6V11211560_enUS_b
Building Technologies
2019-01-15
2.3.3.1 Using the Advanced integration function
After the data points from a device have been integrated to the Desigo Control Point
device, the Advanced integration manually adds or removes individual BACnet objects
for monitoring. For example, you can select Basic operation as the Integration level for
an individual DXR. After data points from the DXR are integrated, you can manually
add objects to use for troubleshooting.
Figure 2: Example of Advanced integration function with two objects manually added and one removed.
Using the Advanced data point integration function
Data points have already been integrated from the device that contains the desired
BACnet objects.
1. Select > > Data point integration.
2. Click Advanced for the device that contains the desired BACnet objects.
The Advanced page displays the tree view for the selected device.
3. Navigate through the building structure to locate the desired BACnet objects.
If a check box is selected, the BACnet object is already included in the
integration function either because it was included in the selected Integration
level, or it was previously manually-selected.
4. Select the check box for any BACnet objects to be integrated.
5. Clear the check box for any BACnet objects to be removed from monitoring.
6. Click Apply to save your changes.
The Data point integration list is displayed.
7. Select the check box(es) for the device(s) that were updated and click Integrate to
update the data points that are being monitored.