Operating instructions

Commissioning (software)
2.6 Parameterization with STARTER
Control Units CU240S
Operating Instructions (Compact), 04/2006, A5E00766042B AA
2-15
STARTER projects
Using STARTER either a new project can be created or an already existing project can be
opened.
To create a new project in STARTER one of the following methods can be used:
Search inverter
Wizard
Select inverter.
When opening an existing project or creating a new project STARTER is in the offline mode.
To go online the button
has to be pressed.
Changing parameters with STARTER
Parameters can be changed online or offline (online preferred).
Online parameter changes are stored in the RAM of the inverter. A manual transfer from
RAM to EEPROM can be triggered by pressing
. When closing STARTER and the
contents of the RAM and EEPROM are different, the user is asked whether or not they wish
to transfer the RAM data to the EEPROM.
Note
Via P0014 the store mode can be changed,
P0014 = 0: parameter changes stored in RAM (default)
P0014 = 1: parameter changes stored in EEPROM
Parameter sets that have been changed offline can be transferred to the inverter using the
download
button.
Caution
Parameters for fail-safe functions can only be changed in the online mode.
When downloading parameters via STARTER, parameters belonging to fail-safe functions
will not be downloaded.