Operating instructions

Commissioning (software)
2.5 Parameterization with MMC
Control Units CU240S
2-14 Operating Instructions (Compact), 04/2006, A5E00766042B AA
2.5 Parameterization with MMC
Overview
A G120 inverter can be parameterized by downloading a parameter set from the MMC to the
inverter.
The download can be performed as
manual download
automatic download
start-up download
A detailed download description can be found in the operation section.
2.6 Parameterization with STARTER
2.6.1 Commissioning with STARTER
Commissioning with STARTER
The following interfaces - which are Control Unit dependent are available:
Table 2-15 Connection possibilities for STARTER
Type USS on RS232 USS on RS485 PROFIBUS DP
PC connected to CU
via
PC Connection Kit Sub D cable & RS485 to
RS232 converter
DP interface
Interface Option port Sub D connector Sub D connector
Restrictions Peer to peer up to 31 slaves up to 125 slaves
CU240S X X --
CU240S DP X -- X
CU240S DP-F X -- X
General information for connecting STARTER
USS address: see P2011, default setting P2011 = 0
USS baudrate: see P2010, default setting P2010 = 8 (≙ 38400 baud)
PROFIBUS-DP address: see P0918 or PROFIBUS-DP DIP switches.