Operating instructions

Commissioning
5.5 Commissioning using the BOP
Control Units CU240S
92 Operating Instructions, 10/2007, A5E00766042B AC
Contents of a complete acceptance test
Documentation
Documentation of the machine including the fail-safe functions.
Machine description and overview/block diagram
Fail-safe functions for each drive
Description of the fail-safe devices/equipment.
Function test
Checking the individual fail-safe functions that are used.
"Safe Torque Off" (STO)
"Safe Stop 1" (SS1)
"Safely-Limited Speed" (SLS)
"Safe Brake Control" (SBC).
Completing the log
Document/log the commissioning phase and sign.
Check the parameters of the fail-safe functions
Document/log the checksums
Provide proof that data has been backed-up/archived
Sign.
Attachment
Measuring traces/plots associated with the function test.
Alarm logs
Trace plots.
Note
A form for an acceptance log is attached in the appendix of the operating instructions.