Operating instructions
Commissioning
4.7 Data backup with the operator panel and memory card
CU240S and CU240E Control Units, FW 3.2
Operating Instructions, 03/2009, A5E02440075B AA
79
Transferring the parameters from the MMC memory card into the inverter (download)
Table 4- 16 Transferring data from the memory card to the inverter
Parameters Description
P0003 = 3 3: Expert
P0010 = 30 30: Initiating parameter transfer
P0803 = 2 2: Transfer data to the EEPROM (of the inverter) from the MMC. "RDY" LED flashes.
• If the upload procedure is successful, P0010 and P0803 are set to 0 and the "RDY"
LED lights up.
• If the download procedure is unsuccessful, F0061 or F0062 is displayed and the
LED "SF" (red) lights up. In this case, make another attempt to transfer data.