Operating instructions

Functions
5.10 Technological functions
CU240S and CU240E Control Units, FW 3.2
150 Operating Instructions, 03/2009, A5E02440075B AA
Table 5- 66 Parameters for switching the drive data sets:
Parameter Description
P0820 = … 1st cntrol command for switching the drive data sets
Example: When P0820 = 722.0, the system switches from drive data set 0 to drive
data set 1 via digital input 0
P0821 = … 2nd control command for switching the drive data sets
r0051 Displaying the number of the DDS that is currently active
A copy function is available making it easier to commission more than one drive data set:
P0819.0 = … Number of the drive data set to be copied (source)
P0819.1 = … Number of the drive data to which the data is to be copied (target)
P0819.2 = 1 Start copying
For an overview of all the parameters that belong to the drive data sets and can be switched,
see the List Manual.