User Manual

Function diagrams
Safety Integrated Extended Functions
2-600
© Siemens AG 2009 - 2013 All Rights Reserved
SINAMICS G120 CU240B/E-2 Control Units List Manual (LH11), 01/2013
Fig. 2-66 2823 – SSM (Safe Speed Monitor)
r9714
SI Mtn diag v P1 [1/min]
- 2823 -
Function diagram
87654321
fp_2823_97_58.vsd
Safety Integrated Extended Functions
CU240E-2 DP-F/PN-F
12.12.2012 V4.6
SSM (Safe Speed Monitor)
1
0
SI Mtn SSM filt P1
0.00 ... 100.00 [ms]
p9545 (0.00)
SI Mtn SSM filt P2
0.00 ... 100000.00 [µs]
p9345 (0.00)
SI Mtn SSM v_limP1
0.00 ... 100000.00 [1/min]
p9546 (20.00)
SI Mtn SSM hyst P1
0.0010 ... 500.0000 [1/min]
p9547 (10.0000)
SI Mtn SSM v_limP2
0.00 ... 100000.00 [1/min]
p9346 (20.00)
SI Mtn SSM Hyst P2
0.0010 ... 500.0000 [1/min]
p9347 (10.0000)
SI Mtn integ stat
r9722
r9722
.15
0
1
0
1
SI Mtn enable P1
- ... -
p9501 (0000 0000 0000 0000 0000 0000 0000 0000 bin)
SI Mtn enable P2
- ... -
p9301 (0000 0000 0000 0000 0000 0000 0000 0000 bin)
.16 (0000 0000 0000 0000 0000 0000 0000 0000 bin)
.16 (0000 0000 0000 0000 0000 0000 0000 0000 bin)
[0]
1 = SSM
(Speed below limit value)
[2840.5]
SSM: Safe Speed Monitor