User Manual
Parameters
List of parameters
1-356
© Siemens AG 2009 - 2013 All Rights Reserved
SINAMICS G120 CU240B/E-2 Control Units List Manual (LH11), 01/2013
Description: Sets the stop response for the function "Safely-Limited Speed" (SLS).
These settings apply to the individual limit values for SLS.
Value: 0: STOP A
1: STOP B
Index: [0] = Limit value SLS1
[1] = Limit value SLS2
[2] = Limit value SLS3
[3] = Limit value SLS4
Dependency: Refer to: p9331, p9563
Notice: This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note: SLS: Safely-Limited Speed
Description: Sets the tolerance for the function "Safe motion direction" (SDI).
This motion in the monitored direction is still permissible before safety message C30716 is initiated.
Dependency: Refer to: p9365, p9366
Refer to: C30716
Notice: This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note: SDI: Safe Direction
Description: Sets the delay time for the function "Safe motion direction" (SDI). When selecting the SDI function, motion in the
monitored direction is permissible as a maximum for this time; this means that this time can be used for braking
existing motion.
Dependency: Refer to: p9364, p9366
Refer to: C30716
Notice: This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note: SDI: Safe Direction
p9363[0...3] SI Motion SLS stop response (processor 2) / SI Mtn SLS stop P2
PM240
PM250
PM260
CU240E-2_DP_F
CU240E-2_F
CU240E-2_PN_F
Access level: 3 Calculated: - Data type: Integer16
Can be changed: C(95) Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 1 0
p9364 SI Motion SDI tolerance (processor 2) / SI Mtn SDI tol P2
CU240E-2_DP_F
CU240E-2_F
CU240E-2_PN_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: C(95) Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 2824
Min Max Factory setting
0.001 [°] 360.000 [°] 12.000 [°]
p9365 SI Motion SDI delay time (processor 2) / SI Mtn SDI t P2
PM240
PM250
PM260
CU240E-2_DP_F
CU240E-2_F
CU240E-2_PN_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: C(95) Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 2824
Min Max Factory setting
0.00 [µs] 600000000.00 [µs] 100000.00 [µs]