Description: Displays the power-on stator frequency/ primary section frequency for the Lh adaptation for the induction motor
(ASM).
Description: Displays the power-on slip frequency for the Lh adaptation for the induction motor (ASM).
Description: Sets the integral time of the kT adaptation of the motor model for a permanent-magnet synchronous motor (PEM).
Description: Displays the corrective value of the kT adaptation of the motor model for a permanent-magnet synchronous motor
(PEM).
Dependency: Refer to: p0826, p1780
Note: The display of the inactive data sets is only updated when changing over the data set.
Description: Sets the pulse frequency for the converter.
This parameter is pre-set to the rated converter value when the drive is first commissioned.
Dependency: Refer to: p0230
Note: The maximum possible pulse frequency is also determined by the power unit being used.
When the pulse frequency is increased, depending on the particular power unit, the maximum output current can be
reduced (derating, refer to r0067).
If a sine-wave filter is parameterized as output filter (p0230 = 3), then the pulse frequency cannot be set below the
minimum value required for the filter.
r1791 Motor model Lh adaptation power-on frequency / MotMod Lh f_on
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- [Hz] - [Hz] - [Hz]
r1792 Motor model Lh adaptation power-on slip / MotMod Lh fslip
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- [Hz] - [Hz] - [Hz]
p1795[0...n] Motor model kT adaptation integral time / MotMod kT Tn
Access level: 4 Calculated: p0340 = 1,3,4 Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: DDS, p0180
Units group: - Unit selection: - Func. diagram: 6731
Min Max Factory setting
10 [ms] 10000 [ms] 100 [ms]
r1797[0...n] Motor model kT adaptation corrective value / MotMod kT corr
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: DDS, p0180
Units group: - Unit selection: - Func. diagram: 6731
Min Max Factory setting
- [Nm/A] - [Nm/A] - [Nm/A]
p1800[0...n] Pulse frequency setpoint / Pulse freq setp
Access level: 2 Calculated: - Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: DDS, p0180
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
2.000 [kHz] 16.000 [kHz] 4.000 [kHz]