SINAMICS G120 CU240B/E-2 Control Units List Manual (LH11), 01/2013
Dependency: In U/f characteristic operating mode only bit 7 is relevant.
For active motor model feedback (see p1784), the Lh adaptation is internally deactivated automatically.
Note: ASM: Induction motor
PEM: Permanent magnet synchronous motor
When selecting the compensation of the valve interlocking via Rs (bit 7), the compensation in the gating unit is de-
activated and is instead taken into account in the motor model.
In order that the correction values of the Rs, Lh and kT adaptation (selected using Bit 0 ... Bit 2) are correctly
accepted when changing over the drive data set, a dedicated motor number must be entered into p0826 for each
different motor.
Description: Sets the scaling for model fault feedback.
Note: Feeding back the measured model fault to the model states increases the control stability and makes the motor
model rugged against parameter errors.
When feedback is selected (p1784 > 0), Lh adaptation is not effective.
Description: Sets the proportional gain for the Lh adaptation of the motor model for an induction motor (ASM).
Description: Sets the integral time for the Lh adaptation of the motor model for an induction motor (ASM).
Description: Displays the corrective value for the Lh adaptation of the motor model for an induction motor (ASM).
Dependency: Refer to: p0826, p1780
Note: The adaptation result is reset if the magnetizing inductance of the induction motor is changed (p0360, r0382). This
also happens when changing over the data set if a different motor is not being used (p0826).
The display of the inactive data sets is only updated when changing over the data set.
06 Select pole position identification PEM
encoderless
Yes No -
07 Select T(valve) with Rs adaptation Yes No -
10 Filter time combination current like current
ctrl integral time
Yes No -
p1784[0...n] Motor model feedback scaling / MotMod fdbk scal
Access level: 4 Calculated: p0340 = 1,3,4 Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: DDS, p0180
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0.0 [%] 1000.0 [%] 0.0 [%]
p1785[0...n] Motor model Lh adaptation Kp / MotMod Lh Kp
Access level: 4 Calculated: p0340 = 1,3,4 Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: DDS, p0180
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0.000 10.000 0.100
p1786[0...n] Motor model Lh adaptation integral time / MotMod Lh Tn
Access level: 4 Calculated: p0340 = 1,3,4 Data type: FloatingPoint32
Can be changed: U, T Scaling: - Dyn. index: DDS, p0180
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
10 [ms] 10000 [ms] 100 [ms]
r1787[0...n] Motor model Lh adaptation corrective value / MotMod Lh corr
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: DDS, p0180
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- [mH] - [mH] - [mH]