Technical data
CU230P-2 Control Units, Getting Started
A5E02484096, 05/2009
21
The next ON command starts the motor data identification. This completes the first commissioning.
4.2 Restoring the factory settings using STARTER
The inverter is reset to the delivery condition by restoring the parameters to the factory setting.
Note
The reset operation is not applied to parameters p0014, p0100, p0201, p0205 or the communication parameters. Motor
parameters p0300 ... p0311 are suitably preassigned for the power unit.
The inverter must be in the online mode to "Restore factory setting". Communication with the control is interrupted for the
time it takes to restore the factory settings.
Restoring the factory setting is done in the following steps:
● Select the inverter in the directory tree
● Start "Restore to factory settings"