Technical data
CU230P-2 Control Units, Getting Started
A5E02484096, 05/2009
11
Note
Important note for setting the CANopen address
The address can only be set via p8620 if the address 0 or 127 is set on the DIP switches of the Control Unit. If the
address switches are set to a value ≠ 0 or 127, this address is always active and p8620 is read-only.
Arrangement of the DIP switches on the Control Unit and address examples
The arrangement and the values of the individual DIP switches to set the CANopen address are provided in "Interfaces,
connectors, control terminals and LEDs on the CU (Page
3)
Note
A newly set CANopen address will only come into effect after switching off and on again. It is particularly important that any
external 24 V supply is switched off.
For additional information, please refer to the associated operating instructions: