User Manual

3 Function diagrams
3.9 Setpoint channel
SINAMICS G120 CU230P-2 Control Units
628 List Manual, 04/2018, A5E33838102
Fig. 3-64 3011 – Fixed speed setpoints, direct selection (p1016 = 1)
- 3011 -
Function diagram
87654321
fp_3011_97_51.vsd
Setpoint channel
G120 CU230P-2
13.03.2018 V4.7_10
Fixed speed setpoints, direct selection (p1016 = 1)
0 0 0 1
0 0 1 0
1 0 0 0
0 1 0 0
r1024
Speed fixed setp [rpm]
n_setp_fix status
r1025
[2505.6]
p1020
[2505.6]
p1021
[2505.6]
p1022
[2505.6]
p1023
1 = Fixed setpoint, bit 0
1 = Fixed setpoint, bit 1
1 = Fixed setpoint, bit 2
1 = Fixed setpoint, bit 3
r1198.3
r1198
r1198.1
r1198
r1198.2
r1198
r1198.0
r1198
+
+
+
+
+
+
n_set_fixed 1 [rpm]
p1001 [D] (0.000)
n_set_fixed 2 [rpm]
p1002 [D] (0.000)
n_set_fixed 3 [rpm]
p1003 [D] (0.000)
n_set_fixed 4 [rpm]
p1004 [D] (0.000)
1
2
2
2
2
n_set_fix select
1 ... 2
p1016 (1)
1
1
1
[3010]
[3010]
[3010]
[3010]