3 Function diagrams
3.8 Internal control/status words
SINAMICS G120 CU230P-2 Control Units
618 List Manual, 04/2018, A5E33838102
Fig. 3-55 2534 – Status word, monitoring functions 1 (r2197)
- 2534 -
Function diagram
87654321
fp_2534_97_01.vsd
Internal control/status words
G120 CU230P-2
13.03.2018 V4.7_10
Status word, monitoring functions 1 (r2197)
9
10
8
7
6
5
4
3
2
1
0
1
ZSW monitor 1
r2197
r2197
Status word, monitoring functions 1 (r2197)
Bit No.
1 = |n_act| n_min p1080
1 = |n_act| n_set
1 = |n_act| n_standstill p1226
1 = I_act I_threshold p2170
1 = Vdc_act Vdc_threshold p2172
1 = Vdc_act > Vdc_threshold p2172
1 = |n_act| speed threshold value 2 (p2155)
1 = |n_act| > speed threshold value 2 (p2155)
1 = n_act 0
1 = |n_act| > n_max
1 = Speed setpoint - actual value deviation within tolerance t_off
n_act = smoothed speed actual value r2169 [8010.2].
11
12
1 = Load missing
13
14
15
Reserved
Reserved
r2197.0
r2197.1
r2197.4
r2197.5
r2197.11
r2197.2
r2197.6
r2197.9
r2197.3
r2197.7
r2197.8
r2197.10
[8022.8]
[8010.8]
[8011.8]
[8022.8]
[8022.8]
[8010.8]
[8011.8]
[8022.8]
[8022.8]
[8022.8]
[8022.8]
1 = |n_act| > n_max
Reserved
(F07901)
<1>
<1>
r2197.13
From speed signals
From speed signals
From speed signals
From speed signals
From monitoring functions
From monitoring functions
From monitoring functions
From monitoring functions
From monitoring functions
From monitoring functions
From monitoring functions
<1>