User Manual

Communication via EtherNet/IP
4.5 Supported objects
Fieldbuses
102 Function Manual, 04/2018, FW V4.7 SP10, A5E34229197B AE
4.5.1
Supported ODVA AC/DC assemblies
Overview
Number
required/
optional
Type
Name
hex
dec
14 hex
20
Required
Sending
Basic Speed Control Output
46 hex 70 Required Receiving Basic Speed Control Input
Assembly Basic Speed Control, Instance Number: 20, type: Output
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0 Fault
Reset
RUN
Forward
1
2
Speed Reference (Low Byte)
3
Speed Reference (High Byte)
Assembly Basic Speed Control, Instance Number: 70, type: Input
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0 Running
Forward
Faulted
1
2
Speed Actual (Low Byte)
3