User's Manual
Siemens PLT 111 · 1999
4/9
I/O modules
Configuring
Modules which can be used on the I/O bus
Modules which can be used on the I/O bus
The following table does not refer to the availability of modules
but to their approval for use in AS 235 systems.
See overleaf for explanations on the table.
Designation Order No. of
module
Release Re-
marks
Closed-loop control modules
Closed-loop control module
PI controller S
6DS1 400-8AA ≥ 16 1) 14)
6DS1 400-8BA ≥ 1 14)
Closed-loop control module
Controller K
6DS1 401-8AA ≥ 11 1)
6DS1 401-8BA ≥ 1 14)
Closed-loop control module
2 PI controllers
6DS1 402-8AA ≥ 15 1) 14)
6DS1 402-8BA ≥ 1 14)
Closed-loop control module
6DS1 403-8AA ≥ 21 1) 14)
6DS1 403-8BA ≥ 1 14)
6DS1 403-8CA ≥ 1 14)
Closed-loop control module
with NAMUR limits
6DS1 403-8CB ≥ 1 14)
Closed-loop control module S,
configurable
6DS1 408-8BB ≥ 2
SW:B03
14)
Closed-loop control module K,
configurable
6DS1 410-8BB ≥ 2
SW:B03
14)
Closed-loop control module S,
configurable, 2 channels
6DS1 411-8AA ≥ 1
SW:B01
14)
6DS1 411-8RR ≥ 1
SW: > 2
14)
Closed-loop control module K,
configurable, 2 channels
6DS1 412-8AA ≥ 1
SW:B01
14)
6DS1 412-8RR ≥ 2
SW:> 2
14)
Individual control drive modules
Control module for motor
6DS1 500-8BA ≥ 1
Individual control drive module 6DS1 501-8BA ≥ 1
6DS1 501-8BB ≥ 1
Control module 6DS1 502-8BA ≥ 1
Control module 6DS1 503-8BA ≥ 1
Individual control drive module
for valves, 4 channels
6DS1 504-8AA ≥ 3
Individual control drive module
for valves, 8 channels
6DS1 505-8AA ≥ 2
Binary output modules BA
BA
6DS1 603-8AB ≥ 1
BA
6DS1 603-8BA ≥ 1 13)
BA
6DS1 603-8RR ≥ 1
BA (16 x 400 mA) 6DS1 604-8AA ≥ 1 8)
BA
6DS1 605-8AA ≥ 1
BA 16, relays 6DS1 605-8BA ≥ 1
PRA 16, relays, testable
6DS1 606-8BA ≥ 5 1)
Designation Order No. of
module
Release Re-
marks
Binary input modules BE
BE, 16 contacts
6DS1 600-8AA ≥ 5 1)
BE with 48 inputs
6DS1 601-8AA ≥ 3 1) 6)
BE with 48 inputs
with INT + process alarm
6DS1 601-8AC ≥ 2 1) 7)
BE with 48 inputs
with INT as common alarm
module
6DS1 601-8BA ≥ 2 7)
BE input
6DS1 602-8AA ≥ 1
BE 32 channels, floating 6DS1 602-8BA 1; 2;
≥ 4
5) 6)
11)
BE, interrupt, 48 inputs as
common alarm module
6DS1 615-8AA ≥ 4 7)
BE, changeover contacts
6DS1 620-8AA ≥ 5
BE, BERO 6DS1 621-8AA ≥ 5
PBE, testable 6DS1 618-8CA ≥ 4
Metering pulse input module
Metering pulse input module,
8 channels
6DS1 607-8AB ≥ 1 5)
Proportioning counter module
Proportioning counter
6DS1 613-8AB ≥ 7 1)
6DS1 613-8BB ≥ 7 1)
Analog output modules
Analog output, 4 outputs
6DS1 702-8AA ≥ 5 1)
6DS1 702-8RR ≥ 1
Analog input modules
Analog input (8 channels)
6DS1 700-8AA ≥ 10 1) 14)
Analog input (8 channels)
6DS1 700-8AB ≥ 16
SW:1
14)
Analog input (8 channels)
6DS1 700-8BA ≥ 1 14)
Analog input (8 channels)
6DS1 700-8BB ≥ 1
SW:1
14)
Analog input (8 channels)
6DS1 701-8AA ≥ 1
SW:1
14)
Analog input (8 channels),
NAMUR limits
6DS1 701-8AB ≥ 2
SW:1
14)
Measurement-point extension
6DS1 703-8AB =1 14) 17)
6DS1 703-8RR =1 14) 17)
6DS1 713-8AB ≥ 1 14)
Analog input
6DS1 730-8AA ≥ 1 5) 9) 14)
Analog input modules for ther-
mocouples and Pt100
6DS1 731-8AA ≥ 1 5) 9) 14)
6DS1 731-8BA ≥ 1
SW:4
5) 9) 14)
6DS1 731-8EA ≥ 1 5) 9) 14)
6DS1 731-8FA ≥ 1 5) 9) 14)
6DS1 731-8RR ≥ 4
SW:3
5) 9) 14)